中文版
English
Deutschland
Русія
بالعربية
Tiếng Việt
+86-400-808-5226
Home
Power Environmental Monitoring
Power Environmental Monitoring ● Software class
Power Environmental Monitoring ● Equipment category
Modular Data Center
Fuyun Modular Machine Room
Jiyun Modular Machine Room
Ruiyun Modular Machine Room
Xiangyun Modular Machine Room
Cold aisle machine room
Container modular machine room
DCIM
infrastructure management
U position asset management
Capacity management
energy management
IT Operation Management
Report Manager
IT Asset Management
IT asset management
Network Monitoring
LAN monitoring
Digital Twin
3D simulation
Solution
Solutions for small and medium-sized computer rooms
Smart Park Energy Management Solution
Smart Campus Centralized Management Solution
Medical refrigerator monitoring solution
Solution for Environmental Safety Management of Archives
About
Contact
Company Dynamics
Industry dynamics
Tender Information
Dynamic Ring Monitoring Provides Full Service Guarantee for Substation
04
2023
/
12
Guangzhou District Government Construction of Dynamic Environmental Monitoring to Realize Intelligent Management
21
2024
03
Application Value of Digital Twin Combined with Moving Ring Monitoring System
The 3D visualization system of the data center realizes the visualization function on the basis of the traditional data center. Gathering a variety of complex management system information in a virtual simulation environment and displaying it in the most intuitive understanding form, greatly improving the efficiency of information interaction and control, reducing time loss and information waste, and ensuring the timeliness and accuracy of information. Then the end-to-end IT visualization of the data center is realized, strengthen IT control means and management level, including shortening response time to accelerate the process of troubleshooting, improving resource utilization and operational efficiency, and finally complete the efficient, green and intelligent operation of the data center; thus laying a solid foundation for scientific decision-making and effective management of the data center.
01
Current Situation of Power Grid Communication Room (I)
With the development and expansion of the power grid scale, a communication room as a power business data landing point and information transfer station and substation at the same time built. They undertake the independent space for centralized processing, storage, exchange, management and other functions and services of power-related production business data and non-production electronic information generated during the operation of the substation. They support the operation of the communication system from the physical level and are the hub of the communication system and the aggregate of information exchange. The power communication room is usually compared to the "neural node" of the power communication network ".
Location Requirements for Power Grid Communication Room (III)
The location selection of the computer room is an important basic work, which is the need of the continuous operation of the power communication business system, and is also an important means to improve the security level of the computer room. The communication room of the main station is generally placed in the office building, and the communication room of the substation is generally placed in the main control building. Civil structures such as insufficient floor height, insufficient floor bearing and irregular space size are not suitable for planning as machine rooms. Attention should be paid to avoiding the above constraints when selecting sites, and it is better not to choose the top floor, because the top floor is difficult to keep warm and prone to water leakage accidents. If the machine room is set on the first floor, although it is beneficial to consider structural load, lightning induction, equipment handling, etc, however, there are risks of flooding, dusty, infestation and security concerns. Therefore, the smart grid machine room should be set in the middle layer of the building, and take into account the structural load, lightning induction, equipment handling and other factors.
Layout Scheme of Power Grid Modular Machine Room
The standardized module machine room consists of customized integrated racks, screen cabinets, inter-column air conditioners, skylights, end doors and various intelligent micro-information sensing equipment. The main rack of the closed cold channel machine room can be equipped with up to 28 screen cabinets (including equipment screen cabinets, power distribution screen cabinets, wiring screen cabinets and inter-column air conditioners). Divide all kinds of screen cabinets into power distribution area, transmission equipment area, network (dispatching data network, integrated data network, etc.) equipment area, switching equipment area, wiring area, etc. according to the requirements of specific business areas, and reserve 2~3 empty screen cabinets at appropriate positions in each area according to the space usage. Each business screen cabinet is arranged in two columns in the order of "back-to-back and face-to-face.
Successful Cases
See more>
Big Banyan Tree Joins Hands with Baiyun Airport to Build the Foundation of Safety
Big Banyan Tree Guards Power Grid Data Center Security
The wind is up and the rain is falling, and the big banyan tree technology keeps guarding the satellite signal.
News Center
The Big Binian ring guards the holy land of scientific research in Liaoning, and the Institute of Chemical Physics realizes efficient monitoring.
From Temperature to the Guardian of Life: The Power of the Big Banyan Tree Dynamic Ring Monitoring System
Big Banyan Tree Company Helps Insurance Building to Achieve Efficient Operation
GUARDIAN HEALTH, CONNECTS THE MIND -- The Intelligent Innovation Journey of a Community Health Management Station in Shenzhen